VCF 9.1 Readiness Gates: What Held Up and What Didn't
Before I started the upgrade series, I wrote down five readiness gates I’d want in front of anyone booking a window for a 9.0.x to 9.1.x upgrade. Now that I’ve run the whole thing end to end, here’s what held up and what didn’t. This is a nested lab, not production, so read it as a rehearsal and not as evidence.
Gate 1: Prove the upgrade path
The path itself was fine. I went straight from 9.0.2 to 9.1.1, and I took the planner’s vCenter warning for 9.1.1 at face value: the vCenter NTP precheck fails on appliances with a non-UTC time zone, so I put both vCenters on UTC before I started and never found out whether it would have bitten me (Part 4). Where the gate fell short was the build. “9.1.1” isn’t specific enough. My first ESX image was on the 9.1.1.0100 patch build, and Assign Image only offered images on the BOM build, 9.1.1.0.25714478 (Part 5). The inventory in your readiness packet should record the build the upgrade expects, not the newest one you can download.
Gate 2: Treat the management network as a deployment dependency
This one held. The /27 I reserved for the services runtime was enough, and my demo.lab domain passed the FQDN validator, so the .local rejection never applied to me (Part 2). What I’d add is that the address plan isn’t finished after the management services. VCF Automation wanted its own runtime pool and FQDN, and so did log management, so the second round of planning lands in Part 3.
Gate 3: Turn the component list into an owned sequence
The sequence worked, and the capacity part of it is where my lab pushed back. The VCF Automation and log management upgrades stand up new instances beside the old ones, and the upgrade powers the old ones off without deleting them. My management cluster ran short of space, and the prechecks said so: three vSAN what-if errors in Part 4, and two “Are enough resources for EMM present” errors on the ESX precheck in Part 5. I ended up deleting the old appliances and the SDDC Manager snapshot sooner than I’d planned, and the precheck came back clean afterward. Put the cleanup, and the room you need before it, in the change record.
Gate 4: Prove recovery and hand off the Day-2 rules
Most of the evidence was there: SFTP backups for SDDC Manager, file-based backups for both vCenters, NSX Manager backups, and a cold SDDC Manager snapshot. The gap was the components that move to the new lifecycle plane. The on-demand Back Up Now failed for VCF Automation and log management on 9.0.2 with “invalid for backup generation”, so I had no VCF-level backup of either one going into Part 3. If you can’t back a component up before the window, say so in the packet and decide who accepts that.
Gate 5: Put the automation workstation in the change
Nothing needed attention. I used PowerCLI on PowerShell 7 for the snapshots and the deletes, and it behaved.
What the gates didn’t cover
Two things hurt that none of the gates asked about.
The first is the health of each component before the window. My first VCF Automation precheck failed on a platform health check, and I traced it to 976 pods stuck in Pending on the old Automation node (the scheduler had stopped, and nothing restarted it). The log management upgrade failed too, with “Fleet LCM migrate task timed out”, and I ended up deploying log management fresh instead of upgrading it. A pre-window health check of every component, on the component’s own terms, would have caught the first one. It would be my sixth gate.
The second is the platform under the platform. My workload hosts are nested ESX VMs on an NFS datastore, and their virtual NVMe disks had been rejecting UNMAP requests. The ESX remediation failed twice before I found it (Part 6). If you run nested hosts, check the hosts’ own health before the window and not just VCF’s.
The short version
The five gates held up. They didn’t fail me anywhere, but the lab showed me that three of them need more than a pass condition: Gate 1 needs the exact build, Gate 3 needs the room to clean up, and Gate 4 needs a plan for components you can’t back up. If one of them bit you differently, drop a comment and let me know.
-virtualex-